The Trusted Manufacturer of High Pressure Hydraulic Valves
Our AD diaphragm accumulators store hydraulic energy by compressing gas behind a flexible diaphragm. The welded AD series comes in a rechargeable A version and a sealed B version.
Tell us the working pressure range, fluid and amount of fluid the system needs. We can review the size, gas charging arrangement and fluid port for your application.
FIND THE RIGHT CONFIGURATION
Both series provide two operating positions. The main difference is the number of ways and the flow paths available.
Choose A when the gas side needs to be rechargeable. Confirm the precharge requirement and the fluid-port connection for your model.c
Choose B for a permanently sealed gas side. Specify the operating pressure range and required configuration when you order.
AD SERIES DIMENSIONS
Choose the nominal volume first, then verify the pressure specification, diaphragm material and connection for the exact configuration.
Dimensions in mm
Nominal Volume
Body Diameter D
Body Length L
0.075 L
66 mm
65 mm
0.16 L
76 mm
82 mm
0.25 L
85 mm
88 mm
0.32 L
95 mm
95 mm
0.5 L
108 mm
110 mm
0.6 L
115 mm
122 mm
0.75 L
125 mm
127 mm
1.0 L
141 mm
143 mm
1.4 L
158 mm
170 mm
2.0 L
173 mm
212 mm
2.8 L
173 mm
232 mm
3.5 L
173 mm
263 mm
Available nominal pressure ratings are 10, 21 and 33 MPa, depending on the model. The usable oil volume depends on the accumulator size, operating pressure range and gas precharge pressure. Please confirm the specifications for the selected model before ordering.
Dimension note: D and L refer to dimensions shown in the AD series drawing. Overall installed height and connecting dimensions may differ by gas-side and fluid-port configuration. Nominal volume is not the same as usable oil volume.
SECTION VIEWS & CONNECTIONS
Compare the gas charging end, diaphragm position, oil connection and overall dimensions before replacing an existing accumulator.
SELECTION GUIDE
For a new system or replacement, the following information helps confirm the appropriate size and configuration.
01
Identify whether the accumulator will store energy, absorb pressure pulsations or manage pressure changes.
02
Provide minimum and maximum working pressures, required usable oil volume and specified gas precharge.
03
Specify hydraulic fluid, operating temperature and any diaphragm material requirements.
04
Confirm the gas-side version, fluid-port thread, mounting space and installation dimensions.
PRODUCT QUESTIONS
Hydraulic fluid entering the accumulator moves the diaphragm and compresses the gas. The gas can expand and push fluid back into the circuit as pressure falls.
The A version has a rechargeable gas side. The B version has a permanently sealed gas side.
Use the working pressure range and precharge to determine usable oil volume. The nominal volume identifies the accumulator size.c
Send the nameplate, fluid-port thread, installed dimensions and normal operating conditions. A photo of the charging end helps us identify the version.
Talk to our engineering team for product selection, technical support, and customized hydraulic valve solutions.
For a replacement, send a photo of the nameplate. For a new installation, share your working pressure range and the usable oil volume you need.